The Gas-Pro PID gas detector gives you full flexibility to monitor a wide range of gas types and volatile organic compounds (VOCs), perfect for environments with high solvent use. Offering both pumped and diffusion solutions, the Gas-Pro PID offers multiple uses within one compact detector, making it suitable across a wide range of applications.
When working in environments with high in levels of solvents, glues, paints and general volatile organic compounds (VOCs), keeping a close eye on your exposure, gas build up and any potential leaks is vital.
The Gas-Pro PID VOC monitor uses Photo Ionization Detection (PID) technology to allow you to detect hundreds of VOCs, monitoring your safety. With its dual-coloured display, the monitor will alert the user with its 95db audible alarm and its dual-coloured visual alarm bars, so you can respond quickly when it counts.
Crowcon’s PID works with a 10.6 electron volt lamp. This sensor is the most stable sensor on the market, providing detection of a wide range of VOCs. The sensor has an internal UV light source, which the gas sample passes through. An electron is released for gases with an ionization potential of 10.6.
- Detect 100s of VOCs
- Ergonomic design
- te14+ hour battery lifest
- tePumped & diffusion solutionsst
- Monitors 5 gases
| Size | 43 x 130 x 84mm (1.7 x 5.1 x 3.3ins) |
| Weight | 309g 4 gas (10.8oz)/ 340g pumped (11.9oz) 333g 5 gas (11.7oz)/ 362g pumped (12.7oz) |
| Alarms | Audible >95dB @ 30cm (98dB @30cm in loud mode) Visual – all angle dual red/blue LEDs Vibrating alert |
| Display | Top mount for ease of view with dual colour backlight (green/red) |
| Data logging | 125hrs at 10-second intervals (45,000 logs) |
| Event logging | Alarm, over range, calibration, bump, on/off, TWA, 1000 events |
| Battery | Rechargeable Li-ion, >14 hours (13 hours pumped operation) based on CH4, O2, H2S, CO Typical charge time 7.5 hours |
| Sampling | Internal pump as option |
| Operating temperature | -20°C to +55°C (-4°F to +131°F) |
| Storage | -25°C to +65°C (-13°F to +149°F) |
| Humidity | 10 to 95% RH |
| Ingress protection | Independently tested to IP65 |
| Approvals | IECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C ATEX and UKCA: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11 INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
MED Directive 2014/90/EU UKCA MED (MSN1874) |
| Compliance | FCC and CE Complies with EMC Directive 2014/30/EU EN50270 and ICES-003 |
| Interface | Data connection for gas test solutions and direct to PC |
| Charging | Direct connection to multiregional power supply Vehicle charger adaptor Desktop cradle USB power and communications lead |
| Crowcon Connect Compatible? | Yes |
| Gas | Range | Typical Alarms | Resolution |
| PID | 0-1000 ppm | 50 ppm | 1 ppm |
| Ammonia (NH3) | 0-100 ppm | 25 ppm | 1 ppm |
| Ammonia (NH3) | 0-1000 ppm | N/A | 1 ppm |
| Carbon dioxide (CO2) | 0-5% vol. | 0-5% vol. | 0.01% vol. |
| Carbon monoxide (CO) | 0-2000 ppm | 20 ppm | 1 ppm |
| Carbon monoxide (CO) | 0-500 ppm | 20 ppm | 1 ppm |
| Carbon monoxide (hydrogen filtered) |
0-2000 ppm | 20 ppm | 1 ppm |
| Chlorine (Cl2) | 0 – 5 ppm | 0.5 ppm | 0.1 ppm |
| Dual toxic (CO-H2S) | H2S 0-100ppm CO 0-500ppm |
5 ppm 20 ppm |
1 ppm 1 ppm |
| Flammable | 0-100% LEL | 20% LEL | 1% LEL |
| Hydrogen (H2) | 0-1000 ppm | N/A | 1 ppm |
| Hydrogen sulphide (H2S) | 0-100 ppm | 5 ppm | 1 ppm |
| Nitrogen dioxide (NO2) | 0-20 ppm | 1 ppm | 0.5 ppm |
| Oxygen (O2) | 0-25% vol. | 19% / 23% vol. | 0.1% vol. |
| Ozone (O3) | 0-1 ppm | 0.1 ppm | 0.01 ppm |
| Sulphur dioxide (SO2) | 0-20 ppm | 1 ppm | 0.1 ppm |
| Chlorine dioxide (ClO2) | 0-1 ppm | 0.1 ppm | 0.1 ppm |
| Nitric oxide (NO) | 0-100 ppm | 1 ppm | 1 ppm |
JoomShopping Download & Support